Acoustic Doors for High-Performance Sound Isolation

Engineered steel, STC-rated doors designed to maintain personnel and equipment access while controlling sound transmission across professional acoustic walls, studios, industrial enclosures, and specialist facilities

Laboratory-tested acoustic performance up to Rw 63 / STC 64
About 30 minutes average installation time for single-leaf door
Factory-assembled door sets incorporating the leaf, split frame, seals, hinges and selected operating hardware
GET A CUSTOM QUOTE
Definition

What Is a High-Performance Acoustic Door?

A high-performance acoustic door is an engineered doorset designed to control airborne sound while maintaining reliable operation and access. Unlike a standard architectural door, it combines a high-performance steel leaf with an engineered frame, acoustic seals, hinges and hardware to provide consistent sound isolation when closed. Noise-Lock® doors are available in a range of configurations and acoustic ratings to suit different architectural, industrial and security applications.

How Acoustic Doorset Performance Is Achieved?

Acoustic performance is determined by how the individual components work together as an integrated system. An acoustic door can only perform as intended when it is installed as part of a suitably engineered acoustic envelope.
The walls, ceilings and other building elements surrounding the doorset should provide acoustic performance appropriate to the required level of sound isolation.

For desired results, Noise-Lock® doorsets should therefore be integrated with professionally engineered acoustic wall and ceiling systems, ensuring that the surrounding structure does not become a weaker path for sound transmission.

When Installation Costs Matter

Save 30 Minutes on Every IAC Acoustic Door Installation!

Pre-assembled acoustic doors reduce average installation time by at least 30 minutes compared with conventional kit doors. For projects with multiple doors, these savings can significantly reduce overall installation costs.

Technical cross-section of an IAC Noise-Lock® acoustic door showing mineral wool insulation, sealing system, and aluminum profile.
Acoustic Doorsets

Our Acoustic Door Systems

A comprehensive range of high-performance steel acoustic doors designed for architectural, industrial and security applications. Noise-Lock® and Super Noise-Lock® acoustic doors can be engineered with different acoustic ratings, frame configurations, sealing systems, hardware and access-control options to meet project-specific requirements.

IAC Acoustics single-leaf acoustic door with vision panel, shown open to a sound-isolated room.

Single-leaf
Acoustic
Doors

Acoustic single-leaf swing door designed to provide sound isolation up to STC 64 for personnel access in demanding industrial, medical, and architectural acoustic environments.

IAC acoustic double-leaf door installed in an industrial acoustic enclosure

Double-leaf
Acoustic
Doors

Acoustic double-leaf swing door providing up to STC 64 for large opening sound isolation for demanding industrial, medical and architectural acoustic applications.

IAC Acoustics sliding acoustic doors with integrated vision panels in an interior acoustic facility.

Sliding
Acoustic
Doors

Sliding acoustic doors provide a space-efficient solution for special opening requirements while retaining all the performance advantages of Noise-Lock technology.

Bespoke IAC Acoustics acoustic door with integrated personnel door for a specialist acoustic opening.

Custom
Acoustic
Doorsets

Bespoke acoustic doors provide custom-engineered solutions, including vision panels, specialist finishes, fire-rated, RF-shielded and automated configurations.

IAC Acoustic Configurator interface for configuring acoustic testing solutions

Configure Your Acoustic Doorset

Build the right door solution for your project. Choose from a range of options to match your technical and design requirements. Select your door type and model, frame and threshold, fire rating, opening direction and hardware. Define the required door and wall dimensions, add an integrated acoustic vision panel, and customise the finish, colour and leaf/frame appearance. Finally, specify the installation environment and configuration to complete your door setup.

Once submitted, the IAC team will review your project requirements and provide a tailored acoustic doorset recommendation and quotation.

Get a Custom Quote
Featured Product

Noise-Lock® Acoustic Doors and Doorsets 

Noise-Lock is IAC's range of high-performance steel acoustic doors for situations where sound must be reliably contained, and where the door integrates into Moduline acoustic rooms, industrial noise enclosures, studios and existing walls.

IAC Noise-Lock® Acoustic Door Frame Structure

Noise-Lock® Acoustic Door Frame Structure

  1. Architrave
  2. Notch
  3. Wall
  4. Main Frame
  5. Fixing
  6. Plug Button
  7. Corridor Wall
  8. Door Frame
  9. L-Shaped Architrave
  10. Fixing
01

Engineered, Factory-Assembled Steel Door Set

Supplied factory assembled (leafs, frames, seals, hinges and hardware) so operational alignment and sealing are set before shipment; high-performance steel construction with leaf thicknesses of 64 mm, 89 mm and 127 mm depending on the model.

Factory Assembled Avg. 30-Minute Instalation STC-rated
02

Self-Aligning Magnetic Seals and Cam-Lift Hinges

Self-aligning standard magnetic perimeter seals maintain consistent contact around the frame; cam-lift hinges (or block hinges) lift the leaf for clearance on opening and lower it into a controlled bottom seal on closing, without a raised threshold.

Optional D-shape Seals Hinge Options 3 mm Threshold
03

Acoustic Performance of Noise-Lock® and Super Noise-Lock® Doors

The range provides published ratings from Rw 50 / STC 51 to Rw 63 / STC 64, with octave-band sound-transmission-loss data from 63 Hz to 8 kHz. For requirements below Rw 50 / STC 51, refer to the IAC Noishield door range.

Door Model Acoustic Rating Leaf
Thickness
Acoustic
Seals
Octave Band Centre Frequency, Hz Weight
Rw R'w STC NIC 63 125 250 500 1k 2k 4k 8k
Sound Transmission Loss, dB
Noise-Lock® D-50 50 45 51 46 64 mm / 2½" — 22 26 46 50 52 52 58 51 44 kg/m²
Noise-Lock® D-52 52 47 53 48 64 mm / 2½" — 23 30 47 52 54 52 57 55 54 kg/m²
Noise-Lock® D-53 53 48 54 49 89 mm / 3½" — 23 32 52 53 53 52 62 ≥62 78 kg/m²
Noise-Lock® D-59 59 54 61 56 89 mm / 3½" — — 33 54 58 60 62 69 — 80 kg/m²
Noise-Lock® D-63 63 58 64 59 127 mm / 5" — — 40 56 61 64 66 70 — 88 kg/m²
Super Noise-Lock® D-100 50 — — — 102 mm Twin Seal 25 42 52 54 51 60 57 59 69 kg/m²
Super Noise-Lock® D-200 55 — — — 150 mm Triple Seal 39 47 48 60 61 61 55 56 140 kg/m²

Rw is a weighted laboratory sound-reduction index; R'w is the apparent value under installed conditions; STC is the single-number laboratory rating; NIC is the measured isolation between finished spaces. These descriptors are not automatically interchangeable, and octave-band data should be reviewed where low-frequency sources are involved.

04

Integration with IAC Acoustic Systems

Noise-Lock doors integrate with Moduline acoustic rooms and industrial noise enclosures, as well as studios, music rooms and existing wall constructions. This allows the door and surrounding acoustic elements to be coordinated as one complete system.

Moduline Acoustic System Audilogy Booths Acoustiс Test Chambers HVAC Acoustic Louvers
Engineering Design

Engineering Design of Our Acoustic Doors

IAC Acoustics provides high-performance acoustic doors for complex projects requiring multiple capabilities, including sound isolation, fire ratings, blast resistance, RF shielding, CE marking, and SCIF / ICD 705 requirements.

Supported Acoustic Door Features

CE Marking

CE-marked acoustic doorsets support projects requiring conformity with applicable European construction product and doorset standards. Appropriate configurations can be specified to meet relevant regulatory and project requirements.

Fire Ratings

Where acoustic isolation must also provide fire protection, rated door assemblies can be incorporated into the overall design. UL, BS and EN fire-rated configurations are available for applications with specific fire performance requirements.

Blast Resistance

For facilities exposed to pressure events, blast-resistant door assemblies can be engineered to provide both acoustic isolation and structural protection. IAC Noise-Lock configurations are available with blast resistance ratings up to 3 psi.

RF Shielding

Electromagnetic shielding can be incorporated where controlled environments require protection from radio frequency transmission. IAC Noise-Lock doors can achieve RF shielding performance up to 100 dB, subject to the selected configuration and application.

SCIF / ICD 705

Secure facilities can incorporate specialist acoustic doors designed for SCIF applications and enhanced security requirements. IAC Noise-Lock systems can be specified for applications involving ICD 705, JAFAN 6/9 and TEMPEST requirements.

Custom Engineering

Complex projects can combine several performance requirements within a single engineered doorset. Acoustic isolation, fire, blast, RF shielding and security features can be integrated into a tailored solution designed around the specific needs of each application.

Applications

Acoustic Door Applications

Common applications for precise hemi free-field acoustic testing in controlled environments.

01

Industrial Acoustic Doors

02

Architectural Acoustic Doors

03

Medical Acoustic Doors

04

RF & Security Acoustic Doors

Related Projects & Use Cases

Related Case Studies

Discover how our acoustic products and solutions are applied in real-world projects across a range of industries and testing environments.

Why Choose IAC for Acoustic Doors?


Years of Expertise
0 +

IAC combines long-standing acoustic engineering experience, proprietary acoustic doors technologies, standards-led design, and turnkey delivery for turn-key projects worldwide.

Guaranteed Acoustic Performance

Noise control systems are engineered to achieve defined acoustic performance targets, with solutions developed around project-specific noise criteria and compliance requirements.

Application-Specific Engineering

Each solution is engineered for the application, taking account of equipment layout, access, ventilation, maintenance, cleaning and long-term operational requirements.

Rapid, Low-Disruption Installation

Installation methods are planned to minimise construction time, site disruption and interference with ongoing production and industrial operations.

Complete Project Delivery

From acoustic surveys and system design through manufacture, delivery, installation and commissioning, IAC can support the complete noise control project.

Modular & Relocatable Construction

Modular acoustic systems provide durable sound control with reduced structural weight, while panels and enclosures can be dismantled, reconfigured and relocated as operational requirements change.

FAQ

Frequently Asked Questions

If you do not find the answer to your specific technical question here, please contact our engineering team directly.

What acoustic performance can an IAC Noise-Lock door provide?

IAC Noise-Lock acoustic doors are available with published ratings from Rw 50 / STC 51 to Rw 63 / STC 64, with octave-band performance data available for individual models. Higher-performance Super Noise-Lock configurations can provide ratings up to Rw 67 / STC 69. Actual installed performance also depends on the frame, seals, threshold, wall construction and installation.

For acoustic requirements below Rw 50 / STC 51, IAC Acoustics provides the Noishield range. The appropriate door configuration should be selected according to the required acoustic performance and application.

Rw is a weighted sound reduction index determined under laboratory conditions, while R'w is the apparent weighted sound reduction index measured under field conditions. STC is a single-number rating derived from laboratory sound transmission measurements, while NIC is a single-number rating for the measured sound isolation between two spaces in a building. These ratings are based on different standards and measurement conditions and should not be treated as directly interchangeable.

IAC acoustic doors can use rising or cam-lift hinge arrangements that engage the bottom acoustic seal as the door closes. This provides effective sealing without requiring a permanently raised threshold across the doorway.

Yes. IAC acoustic doors are available in single- and double-leaf configurations, with options for custom sizes, designs and specialist features such as vision panels, subject to the selected door construction and performance requirements.

Yes. Specialist IAC door configurations can combine acoustic performance with UL, BS or EN fire resistance, blast resistance and RF / EMI shielding. Shielded acoustic door solutions can provide RF shielding effectiveness of up to 120 dB, depending on the system and application.

Not sure which solution fits your requirements?

Our engineers will help you define the right acoustic test environment based on your application, standards, and constraints.

CONTACT OUR SPECIALISTS